Mechanical installation
Standard devices in a power range of 0.25 ... 3 kW
Mounting in "cold plate" technique
5
l
106
EDS84ASC552 EN 8.1
TopLine
8400GG105a
Fig. 5−14 Dimensions for mounting
d
1
d
2
d
3
d
4
c c
1
c
2
c
3
i j
11
j
21
[kW] [mm] [kg]
E84AVTCC551xxX0
0.55
8.5 12.5 110 105 12 6 6 90 0 > 95 > 95 1.7
E84AVTCC751xxX0
0.75
E84AVTCC112xxX0
1.1
12.5 12.5 135 135 12 6 6 125 0 > 95 > 95 2.2
E84AVTCC152xxX0
1.5
E84AVTCC222xxX0
2.2
E84AVTCC551xxB0
0.55
8.5 12.5 110 105 12 6 6 90 0 > 95 > 95 1.8
E84AVTCC751xxB0
0.75
E84AVTCC112xxB0
1.1
12.5 12.5 135 135 12 6 6 125 0 > 95 > 95 2.3
E84AVTCC152xxB0
1.5
E84AVTCC222xxB0
2.2
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com