Mechanical installation
Standard devices in a power range of 0.25 ... 3 kW
Mounting in "cold plate" technique
5
l
107
EDS84ASC552 EN 8.1
"Slim"
StateLine, HighLine
8400GG105e
Fig. 5−15 Device dimensions
h b t h
1
h
2
t
1
g
1
g
2
[kW] [mm]
E84AVxxC3714xXS
0.37
215 70 163 236 276 150 6 5
E84AVxxC551xxXS
0.55
E84AVxxC751xxXS
0.75
E84AVxxC112xxXS
1.1
270 70 163 295 335 150 6 5
E84AVxxC152xxXS
1.5
E84AVxxC222xxXS
2.2
E84AVxxC3024xXS
3.0
E84AVxxC3714xBS
0.37
215 70 183 236 276 170 6 5
E84AVxxC551xxBS
0.55
E84AVxxC751xxBS
0.75
E84AVxxC112xxBS
1.1
270 70 183 295 335 170 6 5
E84AVxxC152xxBS
1.5
E84AVxxC222xxBS
2.2
E84AVxxC3024xBS
3.0
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com