Wiring the standard device
Basic devices in the power range 0.37 ... 11 kW
Motor connection
5
5.4
5.4.4
5.4-10
EDSVF9333V EN 3.0-06/2005
Features of the connection for motor temperature monitoring:
Pin X8/5, X8/8 from incremental encoder input (X8)
Connection Linear KTY thermal sensor
Tripping point z Warning: Adjustable
z Error (TRIP): Fixed at 150 °C
Notes z Monitoring is not active in the Lenze setting.
z The KTY thermal sensor is monitored with regard to interruption
and short circuit.
PE
UVW
T1T2
U, V, W
T1, T2
0.5...0.6 Nm
4.4...5.3 lb-in
2
1
0
9300vec122
Fig. 5.4-8 Motor connection with KTY thermal sensor
Motor cable
Shield sheet
Securely clamp shield of motor cable with the lugs
U, V, W
Motor cable connection
Observe correct polarity. Observe maximum length of motor cable.
Cable cross-sections up to 4 mm
2
: Use wire end ferrules for flexible cables
Cablecross-sections>4mm
2
: Use pin-end connectors
9300 vector Cablecross-sectionsU,V,W,PE
Type [mm
2
] [AWG]
EVF9321 1 18
EVF9322 1 18
EVF9323 1 18
EVF9324 1.5 16
EVF9325 4 12
EVF9326 6 10
Cable cross-sections

Table of Contents

Other manuals for Lenze 9300 vector Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze 9300 vector Series and is the answer not in the manual?

Lenze 9300 vector Series Specifications

General IconGeneral
BrandLenze
Model9300 vector Series
CategoryDC Drives
LanguageEnglish

Related product manuals