Acceleration, deceleration, braking, stopping
10
Function library
10.7
10.7.1
L
10.7-2
EDS82EV903-1.0-11/2002
l
The acceleration and deceleration times refer to an output frequency
change from 0 Hz to the max. output frequency set under C0011.
l Calculate the times T
ir
and T
if
, which must be set under C0012 and C0013.
T
ir
= t
ir
â‹…
C0011
f
2
− f
1
t
ir
and t
if
are the times required for the change between
f
1
and f
2
:
T
if
= t
if
â‹…
C0011
f
2
− f
1
)
))
) Note!
If the acceleration and deceleration times are set too short the
controller may switch off with TRIP OC5 under unfavorable
service conditions. In these cases, the acceleration and
deceleration times should be set short enough so that the drive
can follow the speed profile without reaching I
max
of the controller.
C0182 = 0.00: Linear ramp function generator operation for the main setpoint.
[ H z ]
2
C 0 0 1 1
1
0
t
i r
t
i f
T
i r
T
i f
t
8200vec527
Fig. 10.7-1 Acceleration times and deceleration times for linear ramp function generator
Adjustment
Linear ramp setting