Important notes
5
Basic device installation
5.2
L
5.2-1
EDS82EV903-1.0-11/2002
5.2 Important notes
l 8200 vector frequency inverters should only be used as built-in units
l If the cooling air contains pollutants (dust, fluff, grease, aggressive gases)
ensure suitable measures to protect the inverter (e.g. filters, regular
cleaning, etc.)
l Free space:
– It is possible to mount several devices side by side with a clearance
depending on the corresponding type.
– Ensure unimpeded ventilation of cooling air and outlet of exhaust air.
– Allow a free space of 100 mm above and below the inverter.
l With continuous vibrations and shocks: Use shock absorbers.
l The indicated dimensions apply to types according to this key:
E82xV xxx K x x xxx 3x 3x
Inverter
Input:
Output:
8200 vector
Type:
_
K
For detailed information refer to the manual
EDK82EV222
Id.-No:
Made in Germany
1D74
Industrial Control
Equipment
D-31855 Aerzen
Hans-Lenze-Str. 1
Prod.-No:
Ser.-No:
Version:
55 Aerzen
Ser.-No:
Version:
Type
E = Built-in unit
D = Built-in unit in push-through
technique
C = Built-in unit in “Cold Plate”
technique
Inverter
Input:
Output:
8200 vector
Type:
_
K
For detailed information refer to the manual
EDK82EV222
Id.-No:
Made in Germany
1D74
Industrial Control
Equipment
D-31855 Aerzen
Hans-Lenze-Str. 1
Prod.-No:
Ser.-No:
Version:
55 Aerzen
Ser.-No:
Version:
Inverter
Input:
Output:
8200 vector
Type:
_
K
For detailed information refer to the manual
EDK82EV222
Id.-No:
Made in Germany
1D74
Industrial Control
Equipment
D-31855 Aerzen
Hans-Lenze-Str. 1
Prod.-No:
Ser.-No:
Version:
55 Aerzen
Ser.-No:
Version:
Power
(e.g.152=15
× 10
2
W=1.5kW)
(e.g.113=11
× 10
3
W=11kW)
Inverter
Input:
Output:
8200 vector
Type:
_
K
For detailed information refer to the manual
EDK82EV222
Id.-No:
Made in Germany
1D74
Industrial Control
Equipment
D-31855 Aerzen
Hans-Lenze-Str. 1
Prod.-No:
Ser.-No:
Version:
55 Aerzen
Ser.-No:
Version:
0.25 ... 11 kW
Voltage class
2 = 230 V
4 = 400 V/500 V
Controller generation
C (0.25 ... 11 kW)
B (15 ... 90 kW)
E82xVxxxK4Bxxx xx xx xxE82xVxxxK4Bxxx xx xx xx
Version, variant
0xx = EMC filter integrated
1xx = For IT systems (15 ... 90 kW)
2xx = Without EMC filter
x0x = Without function ”Safe standstill”
x4x = With f unction ”Safe standstill” (3 ... 90 kW)
xx0 = Not coated
xx1 = Coated
E82xVxxxK4Bxxx xx xx xx
15 ... 90 kW
Hardware version
Software version