Free connection of analog signals
Free configuration of analog outputs
10
Function library
10.12
10.12.2
L
10.12-9
EDS82EV903-1.0-11/2002
The output signal at selection 7 is proportional to the output frequency with slip
compensation.
U
= 6, 00
⋅
f − C0011
V
out
Output signal
out
,
C0011 − C0010
f Output frequency
C0010 Minimum output frequency
C0011 Maximum output frequency
When using no process controller the output signal at selection 8 is proportional
to the output frequency without slip compensation.
The output signal is reciprocal to the output frequency. Thissignal canbe used for
the time indication (e.g. machining time of a product).
Example: Output signal = 0 ... 10 V
U
= 1.00
⋅
C0011
⋅
C0420
V
out
Output signal
out
.
f
128
f Output frequency
C0011 Maximum output frequency
C0420 Gain of analog output
6,00
5,00
4,00
3,00
2,00
1,00
0,00
0
10 20 30 40 50
60
U
out
[V]
f[Hz]
C0420 = 128
8200vec536
Fig. 10.12-1 Output signal of the function ”1/output frequency”
Output signal at selection 7
Output signal at selection 8
Application example for
selection 6