Individual summary of drive parameters in the user menu
10
Function library
10.18
L
10.18-1
EDS82EV903-1.0-11/2002
10.18 Individual summary of drive parameters in the user menu
l Fast access to 10 codes
l Individual combination of 10 codes most important for your application.
Codes for parameter setting
Code Possible settings IMPORTANT
No. Name Lenze Selection
C0517*
v
User menu
• After mains switching or when using the
function
g the code from C0517/1
^
10.18-1
1 Memory 1 50 C0050 Output frequenc y (MCTRL1-NOUT)
will be displayed.
2 Memory 2 34 C0034 Analog setpoint selection range
•
n
enze se
ng,
e user menu con
a
ns
h
m
im
r
n
f
r
in
3 Memory 3 7 C0007 Fixed configuration - digital input signals
the control mode ”V/f characteristic
4 Memory 4 10 C0010 Minimum output frequency
control with linear characteristic”
5 Memory 5 11 C0011 Maximum output frequency
• When the password protection is
6 Memory 6 12 C0012 Acceleration time main setpoint
ac
va
e
,on
y
eco
es en
ere
un
er
C0517 are freel
accessible.
7 Memory 7 13 C0013 Deceleration time main setpoint
.
• Enter the required code numbers in the
8 Memory 8 15 C0015 V/f rated frequency
subcodes.
9 Memory 9 16 C0016 U
min
boost
Codes, which are on ly active when
10 Memory 10 2 C0002 Parameter set transf er
e
ng use
oge
er w
an
lication-I
O
cannot be entered!
Enter the required code number or subcode number into the subcodes under
C0517.
)
))
) Note!
Use the user menu to select ”tailored” codes for your application
to be used by your personnel if the password protection is
activated additionally. Your personnel can only change codes
listed in the user menu.
The personnel operating a transportation system shall be able to change the
speed of the conveyor using the keypad. Thespeed isset and indicated in ”rpm”:
1. Assign C0140 to memory 1 of the user menu (C0517/1 = 140)
2. Delete all other entries from the user menu (C0517/2 ... C0517/10 = 0)
3. Convert the value indicated under C0140 into ”rpm” using C0500/C0501
(¶ 10.16-1)
4. Activate the password protection (C0094 > 0)
5. The current conveyor speed will be indicated after the keypad has been
attached or power on.
6. Use
x to activate the function i and to change the speed during
operation using the
yz keys. The speed set last will be stored when the
mainsisswitchedoff.
Description
User menu adaptation
Example:Select speed via
keypad
User menu configuration