EasyManua.ls Logo

Lenze i550 - Page 157

Lenze i550
196 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Long connecng cables up to max. 5 m
The brake resistor cable must be shielded. The maximum length is 5 m.
For the temperature monitoring cable, twisng is sucient.
R
B
RB1 RB2
< 5 m
T1 T2
+
"
"
Fig. 4: Connecon plan - brake resistor with a cable length of up to 5 m
Wiring to the "brake resistor" connecon on the inverter or another component with brake chopper.
Oponal: Wiring to a control contact, e. g. a digital input that is set to monitor the thermal contact. If the thermal
contact responds, the voltage supply of the inverter must be disconnected (e. g. switch o the control of the mains
contactor).
Electrical installaon
Brake resistor connecon
157

Table of Contents

Other manuals for Lenze i550

Related product manuals