1-phase mains connecon 230/240 V "Light Duty"
Rated data
The output currents apply to these operang condions:
•
At switching frequency 2 kHz or 4 kHz: Ambient temperature max. 40 °C (104 °F).
Inverter I55AP
137D 155D 175D 211D 215D 222D
Rated power P
rated
kW 0.55 0.75 1.1 1.5 2.2 3
Rated power P
rated
HP 0.75 1 1.5 2 3 4
Mains voltage range 1/PE AC 170 V ... 264 V, 45 Hz ... 65 Hz
Output voltage 3 AC 0 - 230/240 V
Rated mains current
without mains choke A 6.9 9.1 12 17.1 20 27.4
with mains choke A -
Apparent output power kVA 1.2 1.6 2.2 2.6 3.6 4.9
Rated output current
2 kHz A 2.9 3.8 5 7.2 8.4 11.5
4 kHz A 2.9 3.8 5 7.2 8.4 11.5
Power loss
2 kHz W 30 38 45 62 79
4 kHz W 32 40 48 66 84
Cyclic mains switching 3 mes per minute
Max. motor cable length
shielded
without EMC category m 50
Category C1 (2 kHz, 4 kHz,
8kHz)
m -
Category C2 (2 kHz, 4 kHz, 8
kHz)
m -
Category C3 (2 kHz, 4 kHz, 8
kHz)
m -
Max. motor cable length
unshielded
without EMC category m 60 80
Degree of protecon
EN IP31
NEMA Type 1
Weight m kg 1.6 2.5
Weight m lb 3.5 5.5
Technical data
1-phase mains connecon 230/240 V "Light Duty"
Rated data
181