3-phase mains connecon 600 V "Light Duty"
Rated data
The output currents apply to these operang condions:
•
At switching frequency 2 kHz or 4 kHz: Ambient temperature max. 40 °C (104 °F).
Inverter I55AP175G I55AP215G I55AP222G
Rated power P
rated
kW 1.1 2.2 3
Rated power P
rated
HP 1.5 3 4
Mains voltage range 3/PE AC 425 V ... 660 V, 45 Hz ... 65 Hz
Output voltage 3 AC 0 - 480/600 V
Rated mains current
without mains choke A 2.7 4.2 6.1
with mains choke A -
Apparent output power kVA 2.7 3.9 6.1
Rated output current
2 kHz A 2 3.2 4.7
4 kHz A 2 3.2 4.7
Power loss
2 kHz W 38 62 79
4 kHz W 40 66 84
Cyclic mains switching 3 mes per minute
Max. motor cable length
shielded
without EMC category m 50
Category C1 (2 kHz, 4 kHz,
8kHz)
m -
Category C2 (2 kHz, 4 kHz, 8
kHz)
m -
Category C3 (2 kHz, 4 kHz, 8
kHz)
m -
Max. motor cable length
unshielded
without EMC category m 60 80
Degree of protecon
EN IP31
NEMA Type 1
Weight m kg 1.7 2.6
Weight m lb 3.7 5.7
Technical data
3-phase mains connecon 600 V "Light Duty"
Rated data
194