Diagnoscs and fault eliminaon
Diagnosc interfaces
The inverter is equipped with an on board micro USB interface.
Depending on the purchase order, the inverter will include one of the following modules:
No module
Keypad
WLAN module
Further informaon on the diagnosc modules can be found here: Download
Micro USB interface
The USB interface must only be used temporarily for the diagnoscs and parameterizaon of the
inverter. It is recommended to always keep the inverter and the diagnosc device on the same earth
potenal or separate the diagnosc device from the mains.
Keypad
4Keypad ^ 173
WLAN module
A connecon to the WLAN module is established using the connecon data.
Connecon data (default sengs)
IP address 192.168.178.1
SSID «Product type»_«10-character idencaon code»
Password password
LED status display
"RDY" LED (blue) "ERR" LED (red) Status/meaning
O O Supply voltage not available.
On On
Inialisaon in progress (inverter is being started.)
Blinks (1 Hz)
O
Safe torque o (STO) acve. The inverter has been inhibited by the integrated safety
system.
Blinks (1 Hz) On
Inverter inhibited, error acve.
On
O
Inverter enabled.
Motor rotates according to the specied setpoint or quick stop is acve.
Both LEDs are blinking in a rapidly
alternang mode
Firmware update acve.
Both LEDs are blinking in a very rapidly
synchronous mode
"Visual tracking" funcon is acve.