Diagnoscs and fault eliminaon
Diagnosc interfaces
The inverter is equipped with an on board micro USB interface.
Depending on the purchase order, the inverter will include one of the following modules:
•
No module
•
Keypad
•
WLAN module
Further informaon on the diagnosc modules can be found here: Download
Micro USB interface
The USB interface must only be used temporarily for the diagnoscs and parameterizaon of the
inverter. It is recommended to always keep the inverter and the diagnosc device on the same earth
potenal or separate the diagnosc device from the mains.
Keypad
4Keypad ^ 173
WLAN module
A connecon to the WLAN module is established using the connecon data.
Connecon data (default sengs)
IP address 192.168.178.1
SSID «Product type»_«10-character idencaon code»
Password password
LED status display
"RDY" LED (blue) "ERR" LED (red) Status/meaning
O O Supply voltage not available.
On On
Inialisaon in progress (inverter is being started.)
Blinks (1 Hz)
O
Safe torque o (STO) acve. The inverter has been inhibited by the integrated safety
system.
Blinks (1 Hz) On
Inverter inhibited, error acve.
On
O
Inverter enabled.
Motor rotates according to the specied setpoint or quick stop is acve.
Both LEDs are blinking in a rapidly
alternang mode
Firmware update acve.
Both LEDs are blinking in a very rapidly
synchronous mode
"Visual tracking" funcon is acve.
Diagnoscs and fault eliminaon
LED status display
175