EasyManua.ls Logo

Lenze i550 - IO-Link

Lenze i550
196 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
IO-Link
Status display
The LEDs indicate the connecon status to the network:
LED "RUN" (green) Status/meaning
O No data transfer.
Blinking
Acve data transfer.
Typical topologies
Tree
M
Dn
D2
D1
M Master D Device
Informaon
Name IO-Link
Specicaon 1.1
Baud rate 230.4 kbaud (COM 3)
Cycle me 2 ms
Port Class A (type A) I max. 200 mA
Connecon designaon
L-
C/Q
L+
X316
IO-Link
L+ 24 V
C/Q Switching and communicaon line
L- 0 V
Cable Spring terminal, 3-pole Standard cable max. 20 m
Connecon descripon IO-Link
Connecon X316
-
Connecon type Non-pluggable
Max. cable cross-secon mm² 1.5
Max. cable cross-secon AWG 16
Stripping length mm 9
Stripping length in 0.35
Required tool 0.4 x 2.5
Electrical installaon
Networks
IO-Link
167