50 | 2-11 FireFighting
Carbon Dioxide
Foropenspillres,thedischargefromthe
hornofaCO2extinguishershouldbefrom
abovethereanddirectedatthebaseof
the ames. This requires getting in close
with the horn to about two or three feet
fromthebaseoftheames.Aslowside-to-
sidesweepingmotionmayalsobeeffective.
For engine compartment res, the
discharge should be directed into the
compartmentthroughanaccessportsoit
isnotnecessarytoopenthecompartment.
CO2 will be effective if the quantity of
extinguishingagentissufcienttodevelop
thenecessaryconcentrationtodisplaceall
theOxygenwithinthecompartment.
For running, dripping res from leaks in
fuellinesortanks,startextinguishmentat
thelowerpartofthereandworkupwards.
Shut off or otherwise stop the leak if
possible.
WARNING
2-11.4 MAINTENANCE OF PORTABLE
FIRE EXTINGUISHERS
Extinguishersshouldbeexaminedatleast
monthlyforatleastthefollowing:
a.They are located in their designated
places,
b.They have not suffered corrosion or
mechanicaldamage,
c. They are fully charged. Those
extinguishers having pressure gauges
orpressureindicatorsshouldshowthat
pressureiswithintheprescribedlimits;
those without pressure gauges or
indicators,andHalonandCO2portable
re extinguishers, should be weighed
and the weight recorded for future
comparison.
d.Thetampersealshouldbeinspectedto
ascertain that the extinguisher has not
beenoperatedsincethelastinspection,
e.Thenozzleoriceshouldbeunobstructed
andthehoseingoodcondition.
After any use, portable re extinguishers
should be recharged by a qualied re
extinguishing service facility or replaced
withaunitofcomparablesize,ratingand
type.
At one-year intervals, a full maintenance
check shouldbe madeby aqualied re
extinguishing system service facility in
accordance with the manufacturer's
maintenanceinstructions.Atagshouldbe
attached showing the date of such
maintenancecheckandtherecommended
dateforthenextcheck.
DANGER
FAILURE TO CHECK THE FIRE
EXTINGUISHERS REGULARLY AND TO
PERFORM ADEQUATE MAINTENANCE
COULD LEAD TO MALFUNCTION OR
NON OPERATION AND RESULT IN
LOSS OF LIFE AND / OR THE VESSEL.