2-25 Optional Extras | 91
2-25.3 Generator Operation
The Genset installation is shown on the
drawing B1 SYS 005 Genset Installation
TheGensetislocatedinthePortside
ForedeckLockerandthecontrolsare
situatedintheInteriorNavStation
electricalcontrolpanelboard.The
GensetisfedfuelfromthePortAftFuel
tankonly.AFueltransferfacilityis
availablefromtheStarboardfueltankto
thePortFueltankandoperatesas
follows:
1) Openthefueltransfervalvesonboth
Port&StarboardFueltanks
2) PresstheFuelTransferButtonatthe
helm station
3) Holdthebuttoninuntilsufcientfuelis
transferred.
NOTE:Nofuelwillbetransferred
unlessthebuttonisheldinandthe
pumpisrunning.
WARNING
WATCH THE PORT TANK LEVEL
DURING TRANSFER TO ENSURE THAT
THE TANK IS NOT OVERFILLED.
EXCESS FUEL WILL ESCAPE FROM
THE BREATHER PIPE INTO THE SEA
CAUSING POLLUTION AND A
POTENTIAL FIRE RISK.
IftheFuelTransferPumpdoesnot
operatecheckthefollowing:
1) CheckiftheWhite10Ampcircuit
breakeratthedistributionpanel
locatedbehindthelockerinthePortaft
cabinhasnottripped.
2) Checkthatthetoggleswitchonthe
fueltransferpumplocatedunderthe
bunkintheStarboardaftcabinisinthe
on position.
3) Checkthatthe25Ampfuseinsidethe
fueltransferpumphousinghasnot
blown.
WARNING
CarefullyreadtheGensetOperator’s
Manualbeforestarting.Followthe
Manufacturer’sRecommendedInspection
andMaintenanceGuidelinesfoundinthe
InstructionManualprovidedwiththe
Vessel.
CAUTION
RefertotheSafetyRulesinthe
Operator’sManualbeforeoperatingor
servicingtheGenset.