1. Operating the Air-conditioning
through the Genset
• OpenallAirconditioning&Gensetsalt
water inlets
• SwitchGensetcircuitbreakertoon
position
• StartGensetallowtorunfor2minutes
minimumbeforeswitchingonAir-con
units.SwitchTransfercircuitbreakerto
on position
• SwitchonselectedAir-concircuit
breaker
NOTE:Ifmorethanoneunitisrequired
donotswitchthemallonatonce.The
initialstart-uploadcouldcausethe
Gensettotrip.Allow1-2minutesbetween
switchingoneachcircuitbreaker.Thiswill
allowtheGensettotakeupthestart-up
loading.OncetheAir-conisrunningselect
requiredtemperatureattheControlpanel
2. Operating the Air-conditioning
through both the Shore Power Cables
• PluginShorepowercables
• SwitchonShorepowercircuitbreaker
• OpenallAir-consaltwaterinlets
• SwitchonselectedAir-concircuit
breaker
• OncetheAir-conisrunningselect
requiredtemperatureattheControl
panel
3. Operating the Air-conditioning
through Single Shore Power Cable
• PlugintheShorepowercable
• SwitchonShorepowercircuitbreaker
• SwitchontheTransferCircuitbreaker
• OpenallAir-consaltwaterinlets
• SwitchonselectedAir-concircuit
breaker
• OncetheAir-conisrunningselect
requiredtemperatureattheControl
panel.