Page 42
FIRE TAMPER
This zone type is used to monitor the wiring to bells and sirens (other than those connected to the Horn Output). The
zone will report trouble if an open, short, or other wiring problem is detected in the supervised bell circuit. This zone
will make a digital dial out when violated. Connect a wire from the Fire Tamper zone (+) to an output configured as a
Sounder.
AUXILIARY
A zone defined as AUXILIARY is ignored for security. It is used to activate macros or as a condition in programming.
This is the default setting for all zones. Zones that are not in use should be configured as AUXILIARY.
KEYSWITCH INPUT
This zone is used to arm AWAY and Disarm the Omni LTe security system using a toggle (to ground) keyswitch or
keypad.
PROGRAMMABLE ENERGY SAVER MODULE
This zone type is for use with the Programmable Energy Saver Modules (PESM). It converts the Zone and the
corresponding Output to operate the PESM. Only Zones 9-16 can be programmed as a PESM.
OUTDOOR TEMPERATURE AND ER OUTDOOR TEMPERATURE
Use this zone type for Outdoor Temperature Sensors. The outdoor temperature can be displayed on the console,
spoken over the telephone, or displayed on an Omnistat Thermostat.
TEMPERATURE AND EXTENDED RANGE TEMPERATURE
The general-purpose TEMPERATURE ZONE type is typically used to monitor indoor temperatures and control
devices. It sets the zone secure/not ready for program conditionals and event button activation.
If FREEZE ALARM is enabled, it reports a potential freeze condition if the temperature falls below 40
o
.
TEMPERATURE ALARM AND EXTENDED RANGE TEMPERATURE ALARM
The TEMPERATURE ALARM ZONE type will generate an alarm (console beeper, no sirens) and dial out if the
temperature goes above the high setpoint or drops below the low setpoint.
HUMIDITY
The HUMIDITY ZONE type is used to monitor indoor and outdoor humidity levels from 0 to 100 percent using the
Model 31A00-2 Indoor/Outdoor Temperature and Humidity Sensor. It sets the zone secure/not ready state for
program conditionals and event button activation programs.
NOTE ON TEMPERATURE AND HUMIDITY ZONE TYPES
Outdoor temperature, temperature, and temperature alarm zone types all have HEAT (LOW) and COOL (HIGH)
setpoints. The zone is "Not Ready" when the temperature is above the high setpoint or below the low setpoint. The
zone is "Secure" when the temperature is between the setpoints. Setting a setpoint to 0 disables the setpoint.
Except for a type 83 and 87, the alarm is not activated. The zone "Not Ready" or "Secure" status is used to activate
button programs and program conditionals.