Action Yes No
Step 17
a Reseat the HVPS cables.
b Check the cables for damage.
Are the cables free of damage?
Go to step 18. Go to step 19.
Step 18
Replace the damaged cable.
Does the problem remain?
Contact the next
level of support.
The problem is
solved.
Step 19
a Check the HVPS characterization.
b Reseat the HVPS cables.
c Check the HVPS cables for proper installation and damage.
d Check the HVPS spring contact for proper connection to the
board.
Is the HVPS properly installed and free of damage?
Contact the next
level of support.
Go to step 20.
Step 20
Replace the HVPS. See
“HVPS removal” on page 231.
Note: Make sure to perform the HVPS characterization when
replacing the HVPS.
Does the problem remain?
Contact the next
level of support.
The problem is
solved.
Clipped pages or images check
Action Yes No
Step 1
a Make sure that the toner cartridge is supported.
b Make sure that the toner cartridge and imaging unit are not
empty.
c Check if the toner cartridge is new.
Is the toner cartridge new?
Go to step 2. Go to step 3.
3400-48x
Diagnostics and troubleshooting
75