3-6 Service Manual
7100-XXX Lexmark confidential until announce edited 1/4/2007
Engine maintenance
This submenu shows the replacement status of the various maintenance items on the MFP. From the top
level of the Maintenance mode menu, use the and keys to navigate to Engine Maintenance. Press
to select the Engine Maintenance item. Use the and keys to navigate to the individual settings
in the Engine Maintenance menu. Press to select the currently displayed item.
Replace OPC Belt
Replace Fuser
Replace TR Belt
Replace PQ Kit
Replace PF1 Kit
Replace PF2 Kit
Replace ADF Kit
Waste Toner Pack Life Setting -
To change the status of any item, use the key to scroll to the desired setting and press the
key.
Press twice to return to the top level of the Maintenance mode menu.
Scan Maintenance
Mono Compression Setting - This item lets you change the scan compression settings. The options are
MH, MR, and MMR. MH is the default setting. This is the only item in the Scan Maintenance menu.
Fax Maintenance
Modem Settings
The three modem settings submenu items can be accessed using the and keys to navigate to the
individual settings. When the desired modem setting is displayed, press to select the item.
RX Level -—This item allows you to adjust the RX level. The options are 16, 26, 33, and 43 dBm. XXX is
the default. This setting is automatically set when the MFP is initialized at setup. Do not change this setting
without second-level support supervision. If the setting needs to be adjusted use the and keys to
navigate to the setting level, and press to select the new setting. Press to exit.
TX Level — This item allows you to adjust the TX level. The options are 0 to 15 dBm. 15 dBm is the default.
This setting is automatically set when the MFP is initialized at setup. Do not change this setting without
second-level support supervision. If the setting needs to be adjusted, use the and keys to navigate
to the setting level, and press to select the new setting. Press to exit.
Cable Equalizer — This setting affect signal attenuation distance and the physical distance the fax can be
from a repeater. The options available for this setting are 0 km, 1.8 km, 3.6 km, and 7.2 km. Do not change
this setting. If the setting needs to be adjusted, use the and keys to navigate to the setting level,
and press to select the new setting. Press to exit.