Repair information 4-41
7100-XXX
HVPS cage removal
1. Remove the HVPS. See “High voltage power supply (HVPS) removal” on page 4-39.
2. Remove the LVPS with cage. See “Low voltage power supply (LVPS) with cage removal” on
page 4-40.
3. Remove three screws (A); remove the HVPS cage.
Toner present sensor removal
1. Remove the HVPS cage. See “HVPS cage removal” on page 4-41.
2. Remove two screws (A); remove the toner present sensor.