Chapter 5 - Parameter List
72
Keypad Display Setting Range
Code
Description
LCD 7-Segment
Frequency Output
Corresponding to Pulse
Input Minimum
Frequency
F freq y1 19 0 to FU1-20 0.01
Pulse Input Maximum
Frequency
F pulse x2 20 0 to 100 [kHz] 0.01
Frequency Output
Corresponding to Pulse
Input Maximum
Frequency
F freq y2 21 0 to FU1-20 0.01
P-Gain for ‘Sub-B’ PG P-gain 22 0 to 9999 1 3000 Yes
I-Gain for ‘Sub-B’ PG I-gain 23 0 to 9999 1 50 Yes
Slip Frequency for
‘Sub-B’ Board
PG Slip Freq 24 0 to 200 [%] 1 100 [%]
P-Gain for
(Sensored) Vector_SPD
ASR P-Gain 25 10 to 500 [%] 0.1
I-Gain for
(Sensored) Vector_SPD
ASR I-Gain 26 10 to 9999 [ms] 1 200 [ms]
Forward Torque Limit Trq + Limit 27 0 to 200 [%] 1 180 [%]
Reverse Torque Limit Trq - Limit 28 0 to 200 [%] 1 180 [%]
-
FDT-1 0
FDT-2 1
FDT-3 2
FDT-4 3
FDT-5 4
OL 5
IOL 6
Stall 7
OV 8
LV 9
OH 10
Lost Command 11
Run 12
Stop 13
Steady 14
INV line 15
COMM line 16
Ssearch 17
Step pulse 18
Seq pulse 19
Ready 20
Trv. ACC 21
Trv. DEC 22
MMC 23
Zspd Dect 24
EXT-30
Multi-Function Output
Terminal ‘Q1’ Define
Q1 define 30
Torq Dect 25
- FDT-1 Yes
Morek IT OÜ, Rauna 24, 76506 Saue Harjumaa, Estonia. www.morek.eu Tel. +372 604 1423 Fax +372 604 1447 morek@morek.eu