Chapter 5 - Parameter List
74
5.6 Communication Group [COM]
COM group appears only when the corresponding Option Boards are installed. Please refer to the option manual for
detail.
Keypad Display Setting Range
Code
Description
LCD 7-Segment
None 0
Device Net 1
Synchro 2
PLC-GF 3
Profibus-DP 4
Digital-In 5
RS485 6
COM-01
Option Board Type Opt B/D 01
Modbus-RTU 7
- None Yes
None 0
Command 1
Freq 2
COM-02
Option Mode Opt Mode 02
Cmd + Freq 3
- None No
COM-03
Option Version Opt Version 03 - - - - No
8 Bit Bin 0
8 BCD 1% 1
8 BCD 1Hz 2
12 Bit Bin 3
12 BCD 0.1% 4
12 BCD 0.1Hz 5
COM-04
Binary Option Input
Selection
D-In Mode 04
12 BCD 1Hz 6
- 8 Bit Bin
Binary Input Filter Value
Digital Ftr 05 2-50 1 15 Yes
Input Torque Limit
(Option)
Opt TrqLmt 06
TrqLmt 1
None Yes
Control Mode Select
(Option)
Opt CntlMode
07
Opt Control 1
None No
COM-10
Device Net ID MAC ID 10 0-63 1 0 Yes
125 kbps 0
250 kbps 1 COM-11
Device Net
Communication Speed
Baud Rate 11
500 kbps 2
- 125 kbps
Device Net Output
Instance
Out Instance 12
101 3
- 20 No
70 0
71 1
110 2
COM-13
Device Net Input Instance
In Instance 13
111 3
- 70 No
COM-17
PLC Option Station
Number
Station ID 17 0 to 63 1 1 Yes
Profibus ID Profi MAC ID 20 0 to 127 1 1 Yes
Output Number Output Num 30 0 to 8 1 3 Yes