09.06
- Put on flange.
NOTE: Chamfered end must face injection pump
body.
- Slightly oil bolts and tighten to a tightening torque of
5 Nm.
- Release bolts again by 60°.
- Carefully turn injection pump counter clockwise up to a
noticeable stop using serrated wrench 8117.