EasyManua.ls Logo

Linde H40D - Checking the Coolant Concentration

Linde H40D
310 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance 5
Engine
4
4
5
5
t3921378
¾ Read off the filling level in filler neck.
Min. marking is the edge (4) of the lower
step.
Max. marking is the edge (5) of t
he upper
step.
Difference in quantity between min. and max.:
approx. 0.75 l
Filling quantity in cooling system
without heating system and
air conditioning:
8.5 l
with heating system and air conditioning:
10.0 l
The frost protection should be sufficient for
temperatures down to -25 °C. The mixture
ratio required here is 40 % coolant additive
and 60 % drinking water.
Mixture ratio for lower t
emperatures:
Temperature
Coolant
additive
Drinking
water
-3C 45% 55%
-3C 50% 50%
-4C 60% 40%
¾ Run engine until coo
ling system has been
bled of air.
¾ Check coolant level.
¾ Fit filler cap (2) and turn to tighten.
¾ Close the bonnet.
Checking the cool
ant concentration
The cooling syst
em must be filled all-year-
round with a mixt
ure of water and phos-
phate-free, gly
col-based coolant additive with
anti-corrosion
additives to prevent lime scale
deposits and dam
age caused by frost and cor-
rosion, and to ra
ise the boiling temperature.
Operating Instructions 394 807 10 01 EN 07/2011 131