-23-
Transmitting delay time
Select an interval (1-99999ms) of one data when transmitting test data.
Repeat transmittion
Mark on this to send data repeatedly.
Transmitting idle time
Select an interval (1-99999ms) of sending data repeatedly.
For low speed data below 300bps, delay time and idle time settings might not
be reected correctly.
For LE-120SA
Measurement Ports
RS-232C
Measure RS-232C port of line monitor.
TTL
Measure TTL (UART) port of line monitor. Select a
voltage level of target devices from 5V, 3.3V, 2.5V and 1.8V.
Following are the input threshold of TTL.
Signal Level VIL(MAX) VIH(MIN)
5V 1.5V 3.3V
3.3V 0.9V 2.0V
2.5V 0.6V 1.6V
1.8V 0.4V 1.2V
Function
It is able to select “Monitor” and “Simulate” for RS-232C port, and select
only “Monitor” for TTL port.

Table of Contents