18
i-Drive Power (optional)
18.1 i-Drive Power System - Basic Description
It is possible to equip the bed with the i-Drive Power wheel. The i-Drive Power helps hospital staff to drive the bed
during patient transport with minimal manpower.
The i-Drive wheel is located in the center of the bed under the undercarriage. i-Drive Power is equipped with its own
battery and charger and it is not dependent on the bed functions so, if discharged you can still use the bed functions.
The bed is equipped with one i-Drive controller. i-Drive is oriented in straight direction of the bed.
18.2 Safety instruction for i-Drive Power
Follow the instructions carefully.
Ensure that the bed is operated exclusively by qualified staff.
Make sure the siderails are pulled up during the transport.
Never use bed positioning buttons during transport.
Never use Fast forward button when descending. The Fast forward button is recommended for use when
ascending as it is more efficient.
Special precaution need to be considered when reversing. Always keep distance from the bed and never
use reverse button when descending or ascending.
Do not use Free Drive to transport on a slope greater than 1 degree unless adequate personnel are
available to manage safe bed transport.
Never use the i-Drive Power to drive the bed up or down the slope that exceeds 6 degrees.
Never leave the bed with an activated i-Drive Power system without supervision of the trained staff.
Always use the regular mechanical brake system to brake and stabilize the bed.
Pay increased attention when driving the bed using i-Drive Power. Be aware of people and objects in
close proximity and avoid collision with them by careful driving, especially by appropriate speed control.
Make sure the bed is unplugged and bed brakes are released before using i-Drive Power.
Push the emergency stop drive button if immediate movement interruption is needed (e.g. to avoid
collision with other persons or objects).
Retract the i-Drive Power wheel to the undercarriage when parking. This will prevent misuse when
unbraking and braking the bed.
The i-Drive Power electromagnetic brake is designed just for temporary bed stop and not for the
permanent parking.
Switch off the i-Drive Power battery prior to long-term storage or transport (see chapter 6.1).
Push the emergency retraction button under the chassis cover to retract the i-Drive Power wheel
in case an of i- Drive Power system failure. This will enable moving the bed to a safe area manually
without using i-Drive Power.
Retract the i-Drive Power wheel to the undercarriage every time you intend to move the bed sideways.
Pay attention to the LED battery status indicator and plan your drive using the i-Drive Power accordingly.
Insufficient battery capacity can cause unexpected complications and risks during the drive.
Always plug the bed in when you finish your drive in order to recharge the battery and keep your bed
ready to go using the i-Drive Power.
The i-Drive Power battery must be replaced every 2 years to maintain proper functions of the i-Drive
Power.

Table of Contents

Other manuals for LINET Multicare LE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LINET Multicare LE and is the answer not in the manual?

LINET Multicare LE Specifications

General IconGeneral
BrandLINET
ModelMulticare LE
CategoryMedical Equipment
LanguageEnglish

Related product manuals