100 CHAPTER 8: PARTS LIBRARY
QUICK LOAD SERVO 80 S2
Note: When attempting to save a part which already exists, a prompt will be displayed to confirm that
the intent is to overwrite the existing parameter settings of that part.
Pressing F1 will overwrite the part. Pressing F4 will abort the operation and NOT overwrite the part.
4. LOADING / DELETING PARTS
Description
Loading and deleting parts from the library requires a few simple steps. When loading a part file, the PLC
retrieves all the parameters associated to the part file and sets them as the current values. When deleting
parts from the library, the part file located on the memory module is permanently erased. Parts can only be
loaded and deleted if the bar feed is in stop mode and the loading table is in its lower position.
Step 1: Navigate to the last page of the Part Setup menu.
Step 2: Press the up arrow key to enter the Parts Library.
Step 3: Press the F1 key (LOAD). Use the up / down / left / right arrow keys to enter a Part
Number. Once the part number has been established, press the F3 (ENTER).
Note: When attempting to load a part, a prompt will be displayed to confirm that the intent is to load the
part.
PART EXISTNG!
OVERWRITE?
X
PARTS LIBRARY
ACTIVE PART [ #]
TOTAL PARTS [ #]
ESC ENTER
PARTS LIBRARY
ACTIVE PART [ #]
TOTAL PARTS [ #]
LOAD ESC ADD DEL
ENTER PART NUMBER
########
ESC ENTER