Appendix 1. Flag List
A1-
Word Bit Variable Function Description
%FW10
%FW10 _USER_CLK User Clock Clock available for user setting.
%FX160 _USR_CLK0 Setting scan repeat On/Off as much as set scan Clock 0.
%FX161 _USR_CLK1 Setting scan repeat On/Off as much as set scan Clock 1.
%FX162 _USR_CLK2 Setting scan repeat On/Off as much as set scan Clock 2.
%FX163 _USR_CLK3 Setting scan repeat On/Off as much as set scan Clock 3.
%FX164 _USR_CLK4 Setting scan repeat On/Off as much as set scan Clock 4.
%FX165 _USR_CLK5 Setting scan repeat On/Off as much as set scan Clock 5.
%FX166 _USR_CLK6 Setting scan repeat On/Off as much as set scan Clock 6.
%FX167 _USR_CLK7 Setting scan repeat On/Off as much as set scan Clock 7.
%FW11
%FW11 _LOGIC_RESULT Logic result Indicates logic results.
%FX176 _ERR operation error On during 1 scan in case of operation error.
%FX181 _LER Operation error latch Continuously On in case of operation error
%FW14 - _FALS_NUM FALS no. Indicates FALS no.
%FW15 - _PUTGET_ERR0 PUT/GET error 0 Main base Put / Get error.
%FW23 - _PUTGET_NDR0 PUT/GET end 0 Main base Put/Get end.
%FW44 - _CPU_TYPE CPU Type Indicates information for CPU Type.
%FW45 - _CPU_VER CPU version Indicates CPU version.
%FD23 - _OS_VER OS version Indicates OS version.
%FD24 - _OS_DATE OS date Indicates OS distribution date.
%FW50 - _SCAN_MAX Max. scan time Indicates max. scan time.
%FW51 - _SCAN_MIN Min. scan time Indicates min. scan time.
%FW52 - _SCAN_CUR Current scan time Current scan time.
%FW53 - _MON_YEAR Month/year Clock data (month/year)
%FW54 - _TIME_DAY Hour/date Clock data (hour/date)
%FW55 - _SEC_MIN Second/minute Clock data (Second/minute)
%FW56 - _HUND_WK Hundred year/week Clock data (Hundred year/week)
%FD30 - _REF_COUNT Refresh count Increase when module Refresh.
%FD31 - _REF_OK_CNT Refresh OK Increase when module Refresh is normal.
%FD32 - _REF_NG_CNT Refresh NG
Increase when module Refresh is
Abnormal.
%FD33 - _REF_LIM_CNT Refresh Limit
Increase when module Refresh is
abnormal (Time Out).
%FD34 - _REF_ERR_CNT Refresh Error
Increase when module Refresh is
Abnormal.
%FD40 - _BUF_FULL_CNT Buffer Full Increase when CPU internal buffer is full.
%FD41
- _PUT_CNT Put count Increase when Put count.
%FD42
- _GET_CNT Get count Increase when Get count.
%FD43
- _KEY Current key indicates the current state of local key.
%FD44
- _KEY_PREV Previous key indicates the previous state of local key