EasyManua.ls Logo

LT Piccolo 24 - Basic Console Connections; DMX Input and Output

Default Icon
86 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Piccolo 10 from 82
www.lt-light.com
3. BASIC CONECTIONS, ALL MODELS
3.1. DMX-IN & DMX-OUT
Dmx512 output, opto-isolated. Connector: XLR-5 female, standard.
Dmx512 input, opto-isolated. Connector: XLR-5 male, standard.
Pin 1: Ground.
Pin 2: Data
Pin 3: Data +
Pin 4 & 5: No Connection
Always use shielded and twister pairs cables, with 120 ohms of characteristic impedance and low
capacitance. Cable for RS485 data. The Data- & Data + signal have to be in the same twister pair.
Don’t use audio cables
Connect 32 users maximum in a one DMX line
Use cables not over a maximum length of 500 meters
Use a 120 ohms termination, between pin 2 & 3 on the last DMX THRU connector
Use DMX Splitters to connect more DMX users or longer cable runs
Piccolo transmits DMX with following parameters (default configuration*):
PARAMETER
VALUE
DMX512 (1990) NORM
Break Length
95 s
Minimum 88 s
MAB Length
25 s
Minimum 8 s
Bytes/packet
512 channels
1-512 channels
Break to break
25.000 s
170 s 3.000.000 s
Updates/s
40
1-44
(More of DMX configuration in Dmx Setup (33), page-66)
3.2. MIDI IN & MIDI OUT
MIDI standard port: 2 connectors DIN 180º - 5 pines (female) for IN & OUT. Use standard MIDI
cables.
MIDI-IN Pin 1: n.c. MIDI-OUT Pin 1: n.c.
MIDI-IN Pin 2: n.c. MIDI-OUT Pin 2: Ground
MIDI-IN Pin 3: n.c. MIDI-OUT Pin 3: n.c.
MIDI-IN Pin 4: Signal MIDI-OUT Pin 4: Return
MIDI-IN Pin 5: Return MIDI-OUT Pin 5: Signal
PUSH
1
1

Table of Contents