363-206-295
Circuit Pack Descriptions
Issue 1 December 1997 7-11
BBG8/BBG8B SYSCTL Quick Reference
Summary 7
Interface Functions 7
Intra-shelf interface functions performed by the SYSCTL are as follows:
Direct control of other circuit packs via a serial control link and intra-shelf
control bus
Control of circuit pack and user panel LEDs
Detecting the presence of, and identifying, circuit packs installed in the
system.
Craft Interface:
Local and remote craft interface automatically provisioned to 300, 1200,
2400, 4800, 9600, or 19,200 baud
Provides interface for all advanced provisioning, PM, administration, and
maintenance activities.
User Panel 7
Alarm and status indicators
Controls.
Telemetry Functions 7
Telemetry functions provided by the SYSCTL are as follows:
Miscellaneous discrete environmental alarms and control.
Maintenance Functions 7
Maintenance functions provided by the SYSCTL are as follows:
Automatic reset on powerup
Fault detection, isolation, and reporting
Protection switching control of other circuit packs
Inventory information (