363-206-295
Maintenance Description
9-32 Issue 1 December 1997
Table 9-4. Performance Monitoring Parameters (Cont)
Facility Measured Parameter
DS3 Path
for P-Bit,
F&M Bit, and
C-Bit (From
Fiber and DSX)
CV-P Coding Violations
Severely Errored Frame Seconds (SEFS)
ES-P Errored Seconds
SES-P Severely Errored Seconds
UAS-P Unavailable Seconds
DS3 Line Line Coding Violations (CVL)
Errored Seconds (ESL)
Severely Errored Seconds (SESL)
∗ 21G-U OLIU only.
† 23G/23G-U and 23H/23H-U OLIUs only.
‡ Current and previous day parameters only.