363-206-295
Technical Specifications
10-8 Issue 1 December 1997
Line AIS
B2 thresholding signal fail
B2 thresholding signal degrade.
B2 signal degrade thresholds are user settable in the range from
10
-5
to 10
-9
BER.
Performance Monitoring (see Table 10-14)
Section severely errored frame seconds (SEFS)
Line parameter B2
Laser bias current (21G/21G-U only)
Transmit power (21G/21G-U only)
Receive power.
IS-3 Interface (21D/21D-U OLIU)
10
Optical Specification
The 21D/21D-U OLIU is a short-reach optical interface used to
interconnect between the DDM-2000 OC-3 and OC-12 Multiplexers. The
nominal line rate is 155.520 Mb/s. The LED transmitter supplies an
NRZ-coded signal.
Table 10-4, Table 10-5, and Table 10-6 provide detailed specifications and
link budget information for the 21D/21D-U OLIU.
Alarm Thresholding
The following parameters are monitored at the OC-3 interface.
LOS
LOF
LOP
Line AIS
B2 thresholding signal fail
B2 thresholding signal degrade.
B2 signal degrade thresholds are user settable in the range from
10
-5
to 10
-9
BER.
Performance Monitoring (seeTable 10-14)
Section SEFS
B2 parameters.

Table of Contents

Other manuals for Lucent Technologies DDM-2000 OC-12

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies DDM-2000 OC-12 and is the answer not in the manual?

Lucent Technologies DDM-2000 OC-12 Specifications

General IconGeneral
BrandLucent Technologies
ModelDDM-2000 OC-12
CategoryMultiplexer
LanguageEnglish

Related product manuals