28
5.8 Changing to Dynamic Max, Min or TIR Operation (M2 X1)
1) Simultaneously press and hold M/OFF (1), then quickly press and release inch/
mm (2) once to enable the setup mode. (M1 icon appears in the lower left cor-
ner of the LCD) (Figure 3).
2) Continue to press and release M/OFF until the M13 icon is displayed, signifying
the unit is in the selectable resolution mode.
3) Press and hold M/OFF for 2 seconds until the M3 icon appears signifying that
the unit is in the Multiplier Mode (Default Value 1.000).
4) Press and release the M/OFF button until the display shows the
M2 X1 icon. The display shows the current setting.
Figure 17 - Mode of Operation Select Display
The indicator arrives in the live static mode of operation. This is indicated by the
full analog bargraph as shown above. There are four selections available all
determined by the analog bargraph format. The four selections are:
• a live static display of the reading (normal)
• a dynamic maximum of the reading (max)
• a dynamic minimum of the reading (min)
• a dynamic (max-min) of the reading (TIR)
5) Press and release the ZERO/ON button to sequence through the four modes of
operation options: