FILLING UP THE OIL
- Refit and tighten the drain plug 2 (tightening torque 29 to 39 N.m).
- Fill up with oil (see: 3 - MAINTENANCE: LUBRICANTS AND FUEL) through the filler
hole 10.
- Observe the oil level on dipstick 11; the oil level should be at the level of the black point.
- Check for any possible leaks at the drain plug.
- Refit the filler hole 3.
HYDRAULIC CIRCUIT DECONTAMINATION
- Leave the I.C. engine running (accelerator pedal at halfway travel) for 5 minutes
without using anything on the telehandler, then for 5 more minutes while fully
using the hydraulic movements (except the steering system and the service brakes).
- Accelerate the I.C. engine at full speed for 1 minute, then activate the steering
system and the service brakes.
- This operation makes a pollution abatement of the circuit possible through the hydraulic return oil filter.