EasyManua.ls Logo

Manitowoc MLC300 - Page 97

Manitowoc MLC300
280 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Reference Only
Manitowoc Published 11-22-17, Control # 257-02 3-33
MLC300 SERVICE/MAINTENANCE MANUAL ELECTRICAL SYSTEM
3
Table 3-13. IOLC34 Test Voltages
Pin Net Function Voltages
P1-1 GND Ground (from ground stud on rotating bed)
0 V
DC
P1-2 KL15 Control Module Ignition Power (from engine RUN switch)
0 V
DC
Open, 24 V
DC
Closed
P1-3 ID01 System Circulation Filter Switch
0 V
DC
Open, 24 V
DC
Closed
P1-4 ID02 Hydraulic Vacuum Switch
0 V
DC
Open, 24 V
DC
Closed
P1-5 OPH6A18 Digital Pulse Output (not used)
0 V
DC
P1-6 OPH6A19 Digital Pulse Output (not used)
0 V
DC
P1-7 OPH6A20 Not Used
0 V
DC
P1-8 OPH6A21 Not Used
0 V
DC
P1-9 IMID1 Module Identifier Input (from ground stud on rotating bed)
0 V
DC
P1-10 CAN_C—H CAN Bus C—High N/A
P1-11 8C51 (+UB) Battery Power for Control Module Outputs (from CB51)
24 V
DC
P1-12 8C48 (+UE) Control Module Battery Power (from K5)
24 V
DC
P1-13 ID03 Hydraulic Charge Filter Alarm Switch
0 V
DC
Open, 24 V
DC
Closed
P1-14 ID04 Not Used
0 V
DC
P1-15 ID05 Not Used
0 V
DC
P1-16 ID06 Not Used
0 V
DC
P1-17 IDF15 Digital Frequency Input (not used)
0 V
DC
P1-18 IMID2 Module Identifier Input (from ground stud on rotating bed)
0 V
DC
P1-19 CAN_C—L CAN Bus C—Low N/A
P1-20 8C52 (+UB) Battery Power for Control Module Outputs (from CB52)
24 V
DC
P1-21 ID07 Not Used
0 V
DC
P1-22 ID08 Digital Input (not used)
0 V
DC
P1-23 ID09 Hydraulic Vacuum 2 Switch
0 V
DC
Open, 24 V
DC
Closed
P1-24 ID10 Hydraulic Vacuum 3 Switch
0 V
DC
Open, 24 V
DC
Closed
P1-25 ID11 Hydraulic Vacuum 4 Switch
0 V
DC
Open, 24 V
DC
Closed
P1-26 IDF16 Digital Frequency Input (not used)
0 V
DC
P1-27 IACV17 Engine Fuel Level
0.5 to 4.5 V
DC
P1-28 IMID4 Module Identifier Input (from ground stud on rotating bed)
0 V
DC
P2-1 ID12 Not Used
0 V
DC
P2-2 ID13 Digital Input (not used)
0 V
DC
P2-3 ID14 Digital Input (not used)
0 V
DC
P2-4 IACV18 Cooler Fan PSI 4 to 20 mA
P2-5 ODH3A02
24 V
DC
Power Bus:
Flow Sensor
Hydraulic Level Sensor
Hydraulic Charge Filter Alarm Switch
Hydraulic Vacuum Switch
24 V
DC
P2-6 ODH3A04 Rear Alarm (warble)
0 V
DC
Off, 24 V
DC
On
P2-7 ODH3A07 Starter Motor Relay
0 V
DC
Off, 24 V
DC
On