ELECTRICAL SYSTEM MLC300 SERVICE/MAINTENANCE MANUAL
3-34
Published 11-22-17, Control # 257-02
P2-8 ODH3A10
24 V
DC
Power to Hydraulic Vacuum Switches 2, 3, & 4 24 V
DC
P2-9 ODH3A12 Digital Output (not used)
0 V
DC
P2-10 OPH3A15 Digital Pulse Output (not used)
0 V
DC
P2-11 8C53 (+UB) Battery Power for Control Module Outputs (from CB53)
24 V
DC
P2-12 OS85H
8.5 V
DC
Power to Hydraulic Temperature Sensor 8.5 V
DC
P2-13 IACV19 Hydraulic Fluid Level Sensor
0.5 to 4.5 V
DC
P2-14 IACV20 Hydraulic Fluid Temp Sensor
0.5 to 4.5 V
DC
P2-15 ODH3A01
24 V
DC
Power Bus:
• System Circulation Filter
• Cooler Fan PSI
• Engine Fuel Level Sensor
24 V
DC
P2-17 ODH3A09
24 V
DC
Power Bus (not used) 24 V
DC
P2-18 OPH3A14 Digital Pulse Output (not used)
0 V
DC
P2-19 OPH3A17 Digital Pulse Output (not used)
0 V
DC
P2-20 8C54 (+UB) Battery Power for Control Module Outputs (from CB54)
24 V
DC
P2-22 IACV21 Flow Sensor Switch
0 V
DC
Off, 24 V
DC
On
P2-23 IACV22 Analog Input (not used)
0 V
DC
P2-24 ODH3A03 Rear Alarm (positive) 24 VDC
P2-25 ODH3A05
Diesel Heater 28 V
DC
Switched 0 V
DC
Off, 24 V
DC
On
P2-26 ODH3A08 A/C Clutch
0 V
DC
Off, 24 V
DC
On
P2-27 ODH3A11 Gantry Pin Puller Extend Solenoid
0 V
DC
Off, 24 V
DC
On
P2-28 ODH3A13 Gantry Pin Puller Retract Solenoid
0 V
DC
Off, 24 V
DC
On
P2-29 OPH3A16 Digital Pulse Output (not used)
0 V
DC
Pin Net Function Voltages