11
Remark
In case of failure, the display shows " FAIL 00000 ". The
description of the shown error code can be retrieved in the
survey of Nuclei Error Codes (paragraph 5.4). Once an error
occurs, it is not possible to continue the player script. Switch
off the set and restart the player script. By pressing the NEXT
key, it is possible to jump over the failure and to continue the
player script.
Step Description Executing
nucleus
1 Press OPEN/CLOSE and STOP, and turn on the player. 2
2 Display shows "FP SEGMENT". Press PLAY to execute this nucleus. Otherwise press NEXT and go to step 7. 502
3 Starbursts are visible. Press PLAY. 502
4 Horizontal bars are visible. Press PLAY. 502
5 Vertical bars are visible. Press PLAY. 502
6 All segments are visible. Press PLAY. 502
7 Display shows "FP LABEL". Press PLAY to execute this nucleus. Otherwise press NEXT and go to step 13. 503
8 Labels of the first grid are visible. Press PLAY. 503
9 Labels of the second grid are visible. Press PLAY. 503
10 Labels of the third grid are visible. Press PLAY. 503
11 All labels are visible. Press PLAY. 503
12 Standby LED is on. Press PLAY. 503
13 Display shows "FP DIMMER". Press PLAY to execute this nucleus. Otherwise press NEXT and go to step 15. 518
14 Display shows "DIMMING TEST". Wait until it is dimmed, and press than PLAY. 518
15 Display shows "FP KEYBOARD". Press PLAY to execute this nucleus. Otherwise press NEXT and go to step
17.
505
16 Display shows "LKB_0000 N 0". Press all keys at least one time. Press PLAY for a least one-second to exit
this nucleus.
505
17 Display shows "FP REMOTE C". Press PLAY to execute this nucleus. Otherwise press NEXT and go to step
19.
506
18 Display shows "RC C_ N_ 0". Press at least one key of the remote control. Press PLAY to exit this nucleus. 506
19 Display shows "SCART-SW DVD". Press PLAY to execute this nucleus. Otherwise press NEXT. 1408
20 Display shows "COLOUR SETUP". Press PLAY to execute this nucleus. Otherwise press NEXT. 1406
21 Display shows "COLOUR-B ON". Press PLAY to execute this nucleus. Otherwise press NEXT. 120
22 Display shows "PINKNOISE ON". Press PLAY to execute this nucleus. Otherwise press NEXT. 115
23 Display shows "COLOUR-B OFF". Press PLAY to execute this nucleus. Otherwise press NEXT. 121
24 Display shows "PINKNOIS OFF". Press PLAY to execute this nucleus. Otherwise press NEXT. 116
25 Display shows "SINE ON". Press PLAY to execute this nucleus. Otherwise press NEXT and go to step 27. 117
26 Display shows "BUSY". To stop this nucleus, press STOP. 117
27 Display shows "SCART-S PASS". Press PLAY to execute this nucleus. Otherwise press NEXT. 1409
28 Display shows "BE RESET". Press PLAY to execute this nucleus. Otherwise press NEXT. 603
29 Display shows "BE VERSION". Press PLAY to execute this nucleus. Otherwise press NEXT and go to step 31. 602
30 Display shows the version of the basic engine. To stop this nucleus, press PLAY. 602
31 Display shows "BE TRAY OPEN". Press PLAY to execute this nucleus. Otherwise press NEXT. 616
32 Display shows "BE TRAY CLOSE". Press PLAY to execute this nucleus. Otherwise press NEXT. 615
33 Display shows "BE DVD LASER". Press PLAY to execute this nucleus. Otherwise press NEXT. 635
34 Display shows "BE CD LASER". Press PLAY to execute this nucleus. Otherwise press NEXT. 636
35 Display shows "BE LASER OFF". Press PLAY to execute this nucleus. Otherwise press NEXT. 637
36 Display shows "BE FOCUS ON". Press PLAY to execute this nucleus. Otherwise press NEXT. 604
37 Display shows "BE FOCUS OFF". Press PLAY to execute this nucleus. Otherwise press NEXT. 605
38 Display shows "BE DISCM ON". Press PLAY to execute this nucleus. Otherwise press NEXT. 606
39 Display shows "BE DISCM OFF". Press PLAY to execute this nucleus. Otherwise press NEXT. 607
40 Display shows "BE RADIAL ON". Press PLAY to execute this nucleus. Otherwise press NEXT. 608
41 Display shows "BE RADIAL OF". Press PLAY to execute this nucleus. Otherwise press NEXT. 609
42 Display shows "BE SLEDG OUT". Press PLAY to execute this nucleus. Otherwise press NEXT. 611
43 Display shows "BE SLEDGE IN". Press PLAY to execute this nucleus. Otherwise press NEXT. 610
44 Display shows "BE GROOVE IN". Press PLAY to execute this nucleus. Otherwise press NEXT. 612
45 Display shows "BE GROOV MID". Press PLAY to execute this nucleus. Otherwise press NEXT. 613
46 Display shows "BE GROOV OUT". Press PLAY to execute this nucleus. Otherwise press NEXT. 614
47 Display shows "BE RESET". Press PLAY to execute this nucleus. Otherwise press NEXT. 603
48 Display shows "BE TRAY OPEN". Press PLAY to execute this nucleus. Otherwise press NEXT. 616
49 Display shows "BE TRAY CLOSE". Press PLAY to execute this nucleus. Otherwise press NEXT. 615
50 Display shows "ERRORLOG". Press PLAY to execute this nucleus. Otherwise press NEXT and go to step 52. 404
51 Display shows the error codes. With the keys NEXT and PREV it is possible to step through the error codes.
To stop this nucleus, press STOP.
404
52 Display shows "PASS", this means the Player Script is finished and the execution of the User Dealer Script is
started in an endless loop. The execution of the User Dealer Script will only stop, when an error occurs. The
Display shows the error code.
1