PAGE 56 Metor 6M
Installation and Operating Manual
11. ACCESSIBILITY PARAMETERS 92102916 REV 5
11. Select the desired accessibility setting for the menu item using key.
Options are: <HIDDEN>, <READ-ONLY> or <FULL ACCESS>.
12. When the definitions are set, press . Program asks "Quit editing
privileges? OK / C". Press .
13. The text “Operation completed OK” will be displayed.
Disabling keypad
Function can be turned On only with a remote control. When the function is turned
On keypad is not functioning, but remote control is. If remote controls are removed
the function will automatically be turned Off.
If the remote control unit is broken or lost while the keypad disabling function is
turned On, there is a backdoor to turn the function Off:
1. Open the lid below the cross piece.
2. Press the Learn button and keep it pressed until the display asks “Validate
remote?“.
3. Press the OK key on the cross piece keypad.
Keypad is now functioning.