Metor 6M PAGE 57
Installation and Operating Manual
92102916 REV 5 12. STATISTICS
12. STATISTICS
FUNCTION NOTES
PAX
ALM
Displays passenger counter value (“COUNTS nn”).
Displays alarm counter value (“ALARMS nn”)
ALARM RATE
Displays alarm rate percentage (“ALARM%: n”).
NA: 123
RA: 14
NA = number of non-alarming people passed through
RA = number of random alarms generated
These counters are cleared with the 4.3 CLEAR STATISTICS command (numbers above
are examples and might be different on an actual Metor 6M)
ALM:
RND/ALM
ALM = number of natural alarms occurred
RND/ALM = number of random alarms for alarming people generated
COUNT
DIRECTION
Specifies traffic counter’s direction mode.
Possible values are OFF, DIR1, DIR2 or AUTO.
Default value is DIR1.
DECREASE
MODE
Specifies traffic counter’s decrease mode.
Possible values are ON or OFF.
Default value is OFF.
When using random alarm Decrease Mode should be set OFF.
CLEAR
STATISTICS
Clears passenger and alarm counter.
NOTICE
Maximum value of the counters is 4 294 967 295. Should a counter ever reach
its maximum value it will stay at the maximum value. Use “CLEAR
STATISTICS” function to reset counters.
4 STATISTICS
4.1 COUNTER VALUES
4.2 COUNTER PARAMETERS
4.3 CLEAR STATISTICS
4.1.1 PAX / ALM
4.1.2 ALARM RATE
4.1.3 NA / RA
4.1.4 ALM
RND / ALM
4.2.1 COUNT DIRECTION
4.2.2 DECREASE MODE
alarms
passenger
---------------------------
100