PAGE 66 Metor 6M
Installation and Operating Manual
17. MAINTENANCE 92102916 REV 5
17. MAINTENANCE
Error Messages
ERROR MESSAGE INTERNAL ERROR CORRECTIVE ACTION
SYSTEM MESSAGE:
ERROR CODE XXX
Depends on error number; see next
table
Cycle power on the unit, if reappears
contact service
SYSTEM MESSAGE:
MDPU Vcc TOO LOW
Display unit connection cable faulty
Internal failure
Replace cable
Replace MCDS or MELS
SYSTEM MESSAGE:
MDPU TEMP TOO LOW
Ambient temperature is too low Wait for the unit to warm up
SYSTEM MESSAGE:
MDPU TEMP TOO HIGH
Ambient temperature is too high,
direct sunlight to unit
Move the unit to shadow
SYSTEM MESSAGE:
MDPU EEPROM INIT.
Memory was corrupted Cycle power on the unit; verify that all
parameters are correct!
SYSTEM MESSAGE:
ACCESS CODES INIT.
The Learn button was pressed for
more than five seconds
Re-set all access codes
BATTERIES OF REMOTE
CONTROL ARE EMPTY!
Empty batteries on remote control Replace batteries
LOW REMOTE CONTROL
BATTERY LEVEL!
Almost empty batteries on remote
control
Replace batteries soon
SYSTEM MESSAGE:
MCCU Vcc TOO LOW
Power supply failure
MCCU failure
Replace power supply
Replace MELS
SYSTEM MESSAGE:
MCCU TEMP TOO LOW
Ambient temperature is too low Wait for the unit to warm up
SYSTEM MESSAGE:
MCCU TEMP TOO HIGH
Ambient temperature is too high
Electrical failure
Move the unit to cooler place
Replace MELS
SYSTEM MESSAGE:
MCCU EEPROM INIT
Memory was corrupted Cycle power on the unit; verify that all
parameters are correct!
SYSTEM MESSAGE:
RX-CABLE FAILURE!
RX–cable is loose or disconnected Check RX-cable connection
SYSTEM MESSAGE:
TX-CABLE FAILURE!
TX–cable is loose or disconnected Check TX-cable connection