4.3 Additional instruments and optional accessories
52 Titrando Installation Instructions
4.3.12 Cables for electrodes and other accessories
Order no. Description
6.2104.020 Connection cable for Metrohm electrodes with plug head, length 1 m
6.2104.030 Connection cable for Metrohm electrodes with plug head, length 2 m
6.2104.140 Connection cable for resistance thermometer with 2 mm-plug, length 1 m
6.2104.150 Connection cable for resistance thermometer with 2 mm-plug, length 2 m
6.2106.020 Connection cable for reference electrodes, length 1 m
6.2106.060 Connection cable for reference electrodes, length 2 m
6.5104.030 Differential amplifier, 230 V Euro
for measurements in poorly conducting solutions
6.5104.040 Differential amplifier, 115 V USA
for measurements in poorly conducting solutions
4.3.13 Communication
Order no. Description
6.2151.000 Cable for connecting the control device (Ti-
trando, Dosing Interface, Sample Processor,
etc.) to a PC (USB connection, type A) and
for connecting additional control devices
USB A – Controller (1.8 m)
6.2151.020 USB cable for connecting a printer (USB
connection, type B) to the control device (Ti-
trando, Dosing Interface, Sample Processor,
etc.) (USB connection, type A)
USB A – USB B (1.8 m)
6.2148.010 Remote box MSB
for connecting devices controlled by remote
lines (e. g. Sample changer)
6.2148.020 RS232 box USB (USB-RS232 box)
for connecting devices with a serial RS232
interface (e. g. balances) to the USB connec-
tion of the control device (Titrando, Dosing
Interface, Sample Processor, etc.)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Metrohm Titrando and is the answer not in the manual?

Metrohm Titrando Specifications

General IconGeneral
mV Resolution0.1 mV
Temperature Resolution0.1 °C
ApplicationsAcid-base, redox, complexometric, precipitation, Karl Fischer titration
Measuring inputspH, mV, temperature
Stirrer controlIntegrated stirrer control
Softwaretiamo
Titration MethodsMET (Monotonic Equivalence Titration), SET (Fixed Equivalence Titration)
Dosing ResolutionVaries depending on the Dosing device used
Minimum Dosing VolumeVaries depending on the Dosing device used
pH Resolution0.001
InterfaceUSB
Power Supply100 – 240 V AC (depending on the model)
DimensionsVaries depending on the model
WeightVaries depending on the model