410 Appendix H: Parameters Protected By Safes
PRO1 Live Audio System
Operator Manual
EQ safe
This section shows the aux parameters protected by the EQ safe.
Note: Although bands 5 and 6 are not shown above, the items in the table also apply.
Both bands have items 2, 3 and 4, and band 6 also has item 7.
Item Control Parameter
1 EQ switch EQ on/off
2 gain control knob EQ gain level
3 width control knob EQ width
4 freq control knob EQ frequency
5 SHAPE switch Band 1 shelving mode: parametric, warm, high
pass 6dB or high pass 12dB
6 SHAPE switch Band 2 shelving mode: parametric or high pass
24dB
7 SHAPE switch (not
shown in GUI channel
strip above)
Band 6 shelving mode: parametric, soft, low pass
6dB or low pass 12dB
4
2
3
4
2
3
6
2
3
5
2
3
4
1
4
1
4
5/6/7
2
3