Outputs: » transducer drive: » 150 to 315 V peak
(transducer model dependent)
» relays: » 5 alarm/control relays
» 1 form "C" SPDT contact per relay,
rated 5 A at 250 V ac, non-inductive
» all relays are certified for use in equipment where the
short circuit capacity of the circuits in which they are
connected is limited by fuses having ratings not
exceeding the rating of the relays.
» mA output: » 0-20 or 4-20 mA, scalable
» 0.1% resolution
» 1K max load
» communication » Dolphin Compatible via optional
Milltronics ComVerter
Input: » 0-20 or 4-20 mA, from alternate level monitoring
device, scalable
Enclosure: » wall mount: » Type 4X / NEMA 4X / IP 65
» 195 mm (7.7") W x 180 mm (7.1") H x 75 mm (3.0") D
» polypropylene alloy
» rack mount: » DIN 3U/14HP, 4 rail plug in unit
» suitable for standard 84 HP (19") sub rack
» panel mount: » suitable for DIN 43700 72 x 144
standard panel cut-out
Weight: » wall mount: » 1.5 kg (3.4 lb)
» rack mount: » 870 g (1.9 lb)
» panel mount: » 1.1 Kg (2.4 lb)
Approvals: » CE*, FM, CSA
NRTL/C
* EMC performance available upon request.
Transducers
Compatible Models: » ST Ultrason
®
, STH and Echomax
®
series
Refer to the associated instruction manual.
97\03\26
PL-507 162