SPECIFICATIONS
HYDRORANGER PLUS
Power: » dc supply: » 9 - 30 V dc, 8 W, and / or
» ac supply » 100 / 115 / 200 / 230 V ac ± 15%,
50 / 60 Hz, 15 VA
Environmental: » location: » indoor / outdoor
» altitude: » 2000 m max
» ambient temp.: » – 20 to 50°C (– 5 to 122 °F)
» relative humidity: » wall mount: suitable for outdoor (Type 4X /
NEMA 4X / IP 65 enclosure)
» rack and panel mount: 80% for temperatures
up to 31 °C
» installation catagory: » II
» pollution degree: » wall mount: 4
» rack and panel mount: 2
Range: » 0.3 m (1 ft) to 15 m (50 ft) max.
Accuracy: » 0.25% of program range* or 6 mm (0.24"), whichever is greater
Resolution: » 0.1% of program range* or 2 mm (0.08"), whichever is greater
Memory: » EEPROM (non-volatile) no back-up battery required
Programming: » via keypad programmer or Dolphin interface package
Display: » Custom Graphics LCD
» wall mount: » 100 mm (3.9") W x 40 mm (1.6 ") H
» rack/panel mount: » 20 mm (0.8") W x 75 mm (3.0") H
Temperature
Compensation: » – 50 to 150 °C (– 58 to 302 °F)
» integral transducer sensor
» TS-3 temperature sensor
» programmable fixed temperature
Temperature Error: » 0.09% of range with compensation
» 0.17% per °C deviation from programmed temperature
* Program range is defined as the empty distance from the
face of the transducer (P006) plus any range extension (P801).