3-26
Perform SAMPLE CUT to Find out the Cause of Cutting Error.
In case that normal data cutting cannot be performed etc., perform
cutting with the sample stored in this plotter to find out the cause of
cutting error.
1
Press the key in the local
mode.
2
Press the jog key or to select
[SAMPLE CUT] .
3
Press the key.
4
Press the jog key or to select
the SAMPLE DATA to be cut.
• There are two types of samples, “Cut” and “Logo.” If you select “Cut,” proceed to Step 7.
5
Press the key.
6
Select scale factor using the jog key
or key to cut Logo.
• Scale factor: 1 to 999%
7
Press the key for starting cutting.
Result of SAMPLE CUT
Sample data can be cut successfully, but other data cannot.
The host computer is faulty.
Sample data as well as other data cannot be successfully cut either.
Increase the set value of [ADJ-PRS OFS] to raise the pressure for pressing the cutter blade down.
• Execution of SAMPLE CUT will clear the data in the
receiver buffer.
SAMPLE
Cut
SAMPLE“Logo”
DATA CLEAR <ENT>
FUNCTION
SAMPLE CUT <ENT>
Cu t <en t >
ENTER/HOLD
LOGO <en t >
LOGO 100% <en t >
ENTER/HOLD
LOGO 200% <en t >
ENTER/HOLD