4-5
Troubles for which error messages are given on the LCD
4
In Case of Trouble
Error message Cause Remedy
ERR40 MOTOR A
An excessive load was applied to the
sheet feeding motor.
Turn the power off once and turn it on
again.
Change the sheet setting to [HEAVY].
(
P.3-37)
When a roll sheet is used, perform
sheet feeding to draw it out by a
needed length beforehand.
If the same error message still
appears, contact your distributor or a
sales office of MIMAKI.
ERR41 MOTOR B
An excessive load was applied to the
carriage driving motor.
ERR42 A CURRENT
An overcurrent error in the motor in
the sheet feeding direction was
detected.
ERR43 B CURRENT
An overcurrent error in the motor in
the sheet width direction was
detected.
ERR50 ORIGIN
The plotter has failed to detect the
sheet size.
Turn the power off once and turn it on
again.
If the same error message still
appears, contact your distributor or a
sales office of MIMAKI.