3-25
3
Convenient use
Machine settings
It is each type of setting for using this machine more comfortably. [MACHINE SETUP] and [MACHINE
SETUP2] are available in this machine.
The following items are settable in MACHINE SETUP 1, 2.
Item
Set value
*1
*1. The setting at the time of purchase is indicated with the underline.
Outline
Machine Setup
DEODOR-
IZE FAN
*2
*2. DEODORIZE FAN is optional.
STOP TIME
0 ~ 120
~ 240min/
CONTINUE
Setting the time until the rotation of the exhaust
fan is interrupted after the completion of printing.
RENEW ON / OFF
Switching the current operation of the exhaust fan.
DRYNESS FEED ON / OFF
Setting whether feeding for drying a media is per-
formed after the completion of printing or not.
STAMP SETUP ON / OFF
Setting to output the output date and drawing con-
ditions after the completion of printing.
Waste Ink Warning ON / OFF
Setting whether a check message for the waste
ink tank is displayed or not.
Test Draw Arrange
FEED DIR. /
SCAN DIR.
Setting the deployment direction of the test pattern
when performing test printing repeatedly.
CART.PRIORITY
*3
*3. This function is valid only when the 4-color ink set is used.
INK LEVEL
EXP. DATE
Setting a cartridge to be used first for double car-
tridge automatic change function.
ROOM TEMP
Not wait ARR.
Wait arrival
Sets the operation when an error indicating that
the room temperature is out of the usable tem-
perature range occurs.
(P.3-30)
Machine Setup 2
CONFIRM. FEED ON / OFF
The feeding set for checking the result after test
printing is settable.
[BACK FEED] for returning a media to the original
position by pressing the key is settable
when set to “ON”.
TIME SET Setting the present date and time.
UNIT
SETUP
TEMP.
°C (Centigrade)
/°F (Fahrenheit)
Setting a unit of temperature indications.
LENGTH mm
/ inch Setting a unit of length and area indications.
MACHINE NAME 01
~ 99
Setting a machine name (machine No.) for recog-
nizing each machine when plural machines are
connected through USB2.0 interface.
KEY BUZZER ON
/ OFF
Setting a buzzer sound of the time when a key is
pressed.