4-9
Maintaining Capping station
4
Routine Maintenance
6
Fill up the cap with cleaning solution for
maintenance, using a dropper.
• Fill up the cap with cleaning solution on the verge
of overflow from the cap.
7
Close the front cover then
press the key.
8
Set the duration for leaving the cleaning
solution by pressing the keys.
• Set value : 1 to 99 minutes (Unit: minute)
9
Press the key.
• The cleaning solution filled in the cap is absorbed.
• The screen on the right is displayed only for the duration
set in the step 8.
• It returns to the local mode after the duration.
• When nozzle missing is not cleared even after this washing is carried out several times, exe-
cute “When Nozzle clogged after cleaning” ( P.4-16) and “DISCHARGE & WASH” ( P.4-
17) . Contact a distributor or our sales office (a service call) unless the missing is cleared even
after the above.
• Perform the followings unless the cleaning solution has been filled in the machine.
(1) Perform the operations up to the step 5.
(2) Fill the cap with the cleaning solution by using a syringe.
(3) Perform the operations from the step 7.
ST . MA I NTENANCE
LEAV ING T IME :
1
mi n
ST . MA I NTENANCE
LEAV ING T IME :
2
mi n
*Be i ng In i t i a l i zed*
PLEASE WA I T
<LOCAL . 1>