EasyManua.ls Logo

MIMAKI TxF150-75 - Setting Nozzle Checking During Printing; Setting Auto Nozzle Recovery; Setting Judgment Conditions

MIMAKI TxF150-75
100 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-18
Chapter 3 Settings
Setting nozzle checking during printing
Set to ON to check nozzles when the printer is online and
about to begin printing.
1
With the screen in local mode, select
[MENU] > [NOZZLE CHECK], and then
press the [ENTER] key.
The nozzle check menu is displayed.
2
Select [Printing Check] > [ON], and then
press the [ENTER] key.
To disable this nozzle checking, select [OFF].
3
Select [Check Interval] and press the
[ENTER] key.
4
Select a setting item and press the
[ENTER] key.
LENGTH: Checks nozzles after the machine has
fed the specified length of media.
FILE: Checks nozzles after the number of files
printed reaches the specified value.
5
Select a setting value and press the
[ENTER] key.
Setting values vary depending on whether you
have selected [Length] or [File] above.
LENGTH: 0.1–50 m
FILE: 1–300 files
6
Select [Action] > [CLEANING TYPE], and
then press the [ENTER] key.
7
Select the type of cleaning, and then press
the [ENTER] key.
Setting value: OFF / SOFT / NORMAL / HARD
8
Select [Action] > [RETRY COUNT], and
then press the [ENTER] key.
Setting value: 0–3 times
Setting auto nozzle recovery
Set to perform automatic nozzle recovery if nozzle
clogging is detected.
1
With the screen in local mode, select
[MENU] > [NOZZLE CHECK], and then
press the [ENTER] key.
The nozzle check menu is displayed.
2
Select [AUTO NOZZLE RECOVERY] and
press the [ENTER] key.
3
Select a setting value and press the
[ENTER] key.
Setting value: ON / OFF
Setting judgment conditions
Set the conditions that determine nozzle clogging.
1
With the screen in local mode, select
[MENU] > [NOZZLE CHECK], and then
press the [ENTER] key.
The nozzle check menu is displayed.
2
Select [Judgment Condition] and press the
[ENTER] key.
3
Select a color and press the [ENTER] key.
4
Select the number of nozzles that
determines the judgment, and then press
the [ENTER] key.

Table of Contents