3-22
About Nozzle Check MENU
Set operations concerning the nozzle missing detection function.
Nozzle Check MENU table
Function name Set value Default Meaning
Printing Check ( P.3-24) ON/OFF OFF
Set this when you want to conduct nozzle check at the
beginning of online printing.
(ON)
Check
Interval
Length 0.1 to 50.0m 30.0 m Conducts nozzle check at each set length.
FILE 1 to 100 30 file Conducts nozzle check at each set number of files.
*1
*1. When the set length is reached during printing, nozzle check is conducted at the start of the next printing.
Continuation Print Stop/ Continue Stop
If detects a nozzle missing during printing, set whether to
continue or stop the print.
Action
Cleaning
Soft/ Normal
/ Hard
Soft Sets the type of cleaning performed during recovery work.
Retry Count 0 to 3 1 Repeats the retry operation for the set number of times.
Auto Nozzle Recoverry
(P.3-24)
ON/OFF OFF
Set this when you want to conduct automatic nozzle recovery.
(Maximum 16 per 1 nozzle line)
*2
*2. Depending on the print conditions, nozzle recovery is not applied in some cases. ( P.4-15)
Judgement Condition
(P.3-24)
1 to 64 1
Sets how many missing nozzles are detected for “Nozzle
Missing” judgment to be made according to each color.
Nozzle Check
Printing Check
OFF
OFF
Auto Nozzle Recovery
>
Judgment Condition
Nozzle Check
Printing Check
OFF
OFF
Auto Nozzle Recovery
>
Judgment Condition
Nozzle Check
Printing Check
OFF
OFF
Auto Nozzle Recovery
>
Judgment Condition
Nozzle Check
Printing Check
OFF
OFF
Auto Nozzle Recovery
>
Judgment Condition
3 times
MENU
Setup
>
>
Maintenance
>
Machine Setup
Nozzle Check
>
>
Information
>><<
REMOTEMENU
TEST PRINT /
CLEANING
PRE
30°C/40°C
3200mm
Local <Setup 1>
REMOTEMENU
TEST PRINT /
CLEANING
PRE
30°C/40°C
3200mm
Local <Setup 1>
: Press this to select Nozzle Check MENU, or to switch to
the previous screen.
: Press this to switch to the next screen.
: Use these to select a setting item.
: Press this to confirm a setting, etc..
NCU MENUs at-a-glance