3) ...neither the cooling air grill on the right side (EBC10/11/12), nor the one on the left side (EBC12 only),
nor any of the slits (top, bottom) are blocked in any other fashion and that edge distances of min. 50mm
(EBC10/11: top, right side; EBC12: top, right side, left side) are kept for an adequate ventilation;
4) ...the air slits (top, bottom) are vacuum cleaned regularly and the dust filter(s) behind the air grill(s) on the
right and/or left side are regularly checked/vacuum cleaned/washed/replaced (see section 7
"Maintenance and care", p. 47).
CAUTION: Absence of ventilation at the device's place of installation or blocked cooling air in-/outlets of
the device might overheat the device, as well as reduce the dehumidification capacity of the device.
Two hosepipe connections for the air circulation have to be established between each EBC and the case.
Follow the steps described below for each device that shall be connected to the case (includ. every slave
unit, if any):
The device itself is already equipped with two hosepipe fittings. The hosepipe fittings on the case wall need
to be affixed now. You need two hosepipe fittings for every EBC - one for the air inlet, one for the air outlet.
Firstly define the ideal positions of the air in-/outlets on the case so as to best enable an equal distribution of
the conditioned air.
NOTE: The positions shown in Fig. 4 do not represent a general solution or recommendation.
Mind the following rules before deciding:
1) As already mentioned above, all used EBCs should be positioned as close as possible to their respective
cases, though they can also be placed some meters away, if necessary. Due to the growing air resistance
the efficiency of the EBCs diminishes a little with the length of the tubes. Mind the total length of the
hosepipe provided with your EBC.
2) The hoses must not be laid next to heat-emitting parts.
3) In- and outlets (even those of different EBCs) must not be located directly next to each other on the case
wall (you may position inlets next to inlets and outlets next to outlets). If they need to be positioned close
to each other, anyway, the inner construction of the case should be realised along the ideas presented in
Fig. 4.
4) The constructions on the inside of the case should be realised in a way that enables the air to stream
over the whole volume of the case. Should i.e. some air in- and outlets be located behind the same
partition wall or divider, the inlets need to be sealed off from the outlets even if much space is left
Applies analogously to the individual products of series EBC10/11/12 (Rev.3). As of 24.11.2014. Subject
to modification.